top of page
Gold letter P logo on a blue circle background
2 days ago
8 min read

Sketches of earplugs and sound waves

Earplug attenuation testing measures how many decibels of noise a specific earplug blocks when a specific worker has fitted it. The number on the packet comes from a laboratory panel. A fit test tells you what reaches your own ears on site. For crews working around haul trucks, crushers and compressors in the Pilbara, that is the number that decides whether protection is real. We deliver Hearing Protective Device Fit Tests on site, so the check happens where your people work.



TL;DR

 

  • Attenuation is the noise reduction an earplug delivers, in decibels. The packet rating is a group estimate; a fit test measures the individual.

  • Australian classes (1 to 5) and SLC80 values come from laboratory testing under AS/NZS 1270. Real-world results depend on fit, skill and consistent use.

  • A fit test result, the personal attenuation rating (PAR), is compared against your measured noise level. The target range is commonly 70 to 85 dBA under the earplug.

  • Poor results are usually fixable by refitting, retraining or changing size or model, then retesting.

  • Retest at onboarding and whenever the equipment, the worker or the noise changes.

 

Table of Contents

 

 

What attenuation testing actually measures

 

Attenuation is the difference between the noise outside your ear and the noise that gets past the earplug. Two very different things carry that name.

 

Laboratory ratings. SafeWork NSW explains that Australia has two approved methods for rating hearing protectors, with results given as a Class or an SLC80. The class is set under AS/NZS 1270:2002 and printed on the packaging. SLC80 is a figure that at least 80% of wearers in the test group would meet or exceed.

 

Individual fit testing. The National Hearing Conservation Association (NHCA), a US professional body, says group ratings describe noise reduction measured in optimal conditions with a select panel, while fit testing measures the attenuation of one device as fitted by one wearer, which estimates individual protection more accurately.

 

The gap between the two matters. A 2022 study in the Journal of the Acoustical Society of America explains how the US noise reduction rating is built from laboratory averages, then concludes that even derated ratings do not accurately estimate real-world individual attenuation. Its authors say individual fit testing of workers is the better route.

 

If you want the detail on how the Australian and American ratings differ, we cover it in SLC80 vs NRR.


What attenuation testing actually measures

Why the packet rating is not your rating

 

Manufacturers say this themselves. The documentation for a common disposable foam earplug sold in Australia and New Zealand lists an SLC80 of 23 dB (Class 4) tested to AS/NZS 1270, and warns that wearers may get less noise reduction than the label because of variation in fit, fitting skill and motivation.

 

Field evidence shows how large that variation can be:

 

 

Same earplug family, same rating on the packet, very different protection from one person to the next. That spread is why testing the individual is worth the few minutes it takes.

 

How an individual fit test is carried out

 

There are two broad system types, described in OSHA’s fit-testing bulletin. They differ in how they get the measurement, and both give you a personal attenuation figure.

 

Subjective systems

 

The worker responds to test sounds. According to OSHA’s bulletin on hearing protector fit testing, the worker is tested first without protectors and then with them, a process taking about 5 to 10 minutes. These systems can test any earplug, and they need a reasonably quiet space because background noise and existing hearing loss can affect responses.

 

Objective systems

 

Dual-microphone devices measure the sound outside and inside the ear canal, so the worker does not need to respond. The same bulletin says results arrive in a few seconds and are unaffected by background noise or hearing loss. Some systems work only with specific, modified earplug brands.

 

The laboratory reference

 

Behind both sits the reference method. The European fit-testing standard describes it as a real-ear attenuation at threshold test under EN ISO 4869-1, using 16 subjects and one-third-octave noise bands from 125 Hz to 8 kHz. That is why lab ratings are a population figure and fit tests are the practical field tool.

 

Come as you work

 

Safe Work Australia’s Code of Practice says individual fit is critical and that fit should be checked while the worker wears their normal equipment, such as hard hats, dust masks and eye protection. Workers who wear spectacles should be fitted wearing them. In practice, bring the helmet, glasses and respirator you wear on shift.

 

 

Reading the result

 

A fit test returns a personal attenuation rating (PAR): a single decibel figure you subtract from the A-weighted noise level at the workstation to estimate the exposure under the earplug. The NHCA paper says the target range is commonly 70 to 85 dBA. Above 85 dBA is underprotection. Below 70 dBA is overprotection, which can compromise communication and safety awareness.


Reading the result

Worked example. The workplace noise exposure standard in Australia is LAeq,8h 85 dB(A) with a 140 dB© peak. Say a worker at a crusher is exposed to 102 dB(A). With a PAR of 24 dB, the level under the earplug is about 78 dB(A), inside the 70 to 85 range. With a PAR of 12 dB, it is about 90 dB(A), above the standard, even though the packet may say Class 4.

 

Three points help you read results well:

 

  • A number beats pass or fail when noise levels vary or the job needs good situational awareness. OSHA’s bulletin says a numerical PAR is more useful in those cases. It also says a PAR cannot replace the required selection methods when deciding which protectors to supply.

  • Comfort counts. The NHCA notes a comfortable lower-PAR protector may be preferable to an uncomfortable higher-PAR one, and results must be read in the context of the workplace.

  • Wearing time dominates. Safe Work Australia’s Code of Practice illustrates that a protector worn for a full 8-hour shift delivers a 30 dB maximum protection level, but one hour without it drops that to 9 dB. A good fit only protects when it stays in.

 

Fixing a poor fit

 

A low result is information, not a failure. OSHA’s bulletin says that when a worker misses the target, the tester can retrain or refit the worker, choose a different protector and repeat the test until the target is met. It also advises workers to note how a properly seated earplug feels so they can repeat it.

 

Typical fixes:

 

  1. Reinsert with technique. For foam plugs, roll fully, pull the ear up and back, insert and hold until expanded.

  2. Change size. Our article on choosing earplug size shows why a home tug test is not the same as a measured PAR.

  3. Change model. Different canal shapes suit different plugs.

  4. Check for leakage paths. Safe Work Australia lists damage, leaks and inconsistent use as things to verify.

  5. Retest to confirm the new fit.

 

Attenuation can also drift. The brewery study found final readings after two hours ranged from 0.3 to 41 dB, with a mean fall of about 2.4 dB. Its authors recommend wearers refit as soon as the sound level seems to change. Teach crews to refit at breaks, not only at the start of shift.

 

When to retest

 

Retest at onboarding, and again after a change in earplug model, a new piece of head gear, a significant change in noise or a worker’s report of changed hearing. Our guides on earplug fit test frequency and when to retest hearing protection set out the timing alongside audiometry.

 

What Australian rules expect

 

Fit testing sits inside the wider duty to manage noise. The key points from the national model Code of Practice (November 2024), which applies as guidance and is adopted through state and territory WHS laws:

 

  • The exposure standard is LAeq,8h 85 dB(A) and a peak of 140 dB©. Noise should be reduced above that where reasonably practicable, and personal protectors are not the first control.

  • Where workers frequently need protectors above the standard, the person conducting the business must provide audiometric testing under WHS Regulation 58: a baseline within three months of starting, then at least every two years.

  • The Code’s Table 4 recommends protector classes by exposure: Class 1 below 90 dB(A), Class 2 at 90 to under 95, Class 3 at 95 to under 100, Class 4 at 100 to under 105 and Class 5 at 105 to under 110.

  • If audiometry shows a threshold shift or a worker reports tinnitus, the business must review controls and verify that the protector’s performance, condition, fit and use are right.

 

Individual fit testing is the practical way to show the last point. For an overview of building an audit-ready program, see our piece on mobile fit testing for hearing conservation. Check your own state or territory regulator for the version of the rules that applies to you, since WHS laws are adopted separately.

 

Fit testing at your site

 

We offer Hearing Protective Device Fit Tests as part of our training services, delivered on site anywhere in the Pilbara, including remote mine and construction sites, with scheduling outside standard business hours. Our trainers have industry-relevant experience, and we tailor the session to the risks of your operation. Fit testing sits alongside respirator fit testing and our first aid courses, so one visit can cover several compliance needs for the same crew. See the full course list or talk to us about a group booking.


Primetraining

Our view

 

A rating on a packet tells you what a panel of volunteers achieved in a laboratory. It cannot tell you what your operator achieves at the end of a long shift with a hard hat and glasses on.   We think the strongest hearing conservation programs treat the fit test as training, not paperwork. When a worker sees their own number rise after a refit, the lesson sticks in a way a toolbox talk rarely achieves.   That is why we bring testing to the site. Crews in remote locations should not need to travel to prove their protection works, and shift workers should be able to book outside standard hours. Tailoring the session to the job means the earplug is tested with the gear the worker actually wears.   Vapour

 

FAQ

 

How many decibels do earplugs reduce?

 

It depends on the earplug and the person. A common foam plug sold in Australia carries an SLC80 of 23 dB (Class 4) under laboratory conditions. Individual results vary widely, so a fit test is the way to know your own figure.

 

Is there a trick to putting in earplugs?

 

For foam plugs, roll them into a thin, crease-free cylinder, reach over your head to pull the ear up and back, insert and hold until they expand. A good seal usually makes your own voice sound hollow and cupping your hands over your ears changes little.

 

Is a fit test the same as a hearing test?

 

No. Audiometry measures your hearing and is required for workers frequently using protectors above the exposure standard. A fit test measures how much noise your earplug blocks. They complement each other.

 

Do I need to be tested again if I change earplugs?

 

Yes. A new model, size or piece of head gear changes the seal, so retest to confirm the new PAR before relying on it.

 